Morishita, Takatoshi; Ao, Hiroyuki; Ito, Takashi; Ueno, Akira; Hasegawa, Kazuo; Ikegami, Masanori*; Kubota, Chikashi*; Naito, Fujio*; Takasaki, Eiichi*; Tanaka, Hirokazu*; et al.
Proceedings of 2005 Particle Accelerator Conference (PAC '05) (CD-ROM), p.2851 - 2853, 2005/00
In J-PARC linac, a precise alignment of accelerator components is essential for high quality beam acceleration. Markings have been placed on the floor, which act as a reference for the initial alignment at the installation. For a straight line alignment, the wire position sensor is placed on the offset position with respect to the beam center by a target holder. The hydrostatic levering system is used for watching the floor elevation over the long period.
Morishita, Takatoshi; Ao, Hiroyuki; Ito, Takashi; Ueno, Akira; Hasegawa, Kazuo; Ikegami, Masanori*; Kubota, Chikashi*; Takasaki, Eiichi*; Tanaka, Hirokazu*; Naito, Fujio*; et al.
Proceedings of 1st Annual Meeting of Particle Accelerator Society of Japan and 29th Linear Accelerator Meeting in Japan, p.671 - 673, 2004/08
A precise alignment of accelerator components is essential for the J-PARC linear accelerator. The wire position sensor is applied to measure the accelerator component positioning and the ground motion of the building is measured by the hydrostatic leveling sensors. In this paper, the scheme of the alignment system is presented.
Int. J. Supercomputer Appl., 5(3), p.46 - 62, 1991/00
Times Cited Count:1 Percentile:51.29(Computer Science, Hardware & Architecture)no abstracts in English